ICOS Oceans gas bottle inventory

 

Order reference gases

To ensure compatibility of of the ICOS observations with data from other global monitoring networks, the measurements need to be traceable to the respective WMO calibration scales. The CAL is responsible for providing real air reference gas standards for ICOS atmospheric observations. Calibration is done using a set of WMO laboratory standards.

Bottle specs:

- diameter: 204 mm
- height (without gas valve): 960 mm
- gas valve connection: DIN14

 

1.Contact the CAL lab in advance

Please notify the CAL lab via icos-standards@bgc-jena.mpg.de (cc to tost@norceresearch.no) at least two months in advance if you want to order reference gas standards. Please note that the bottles are for the Ocean network.

Keep in mind that the bottles that are in use need to be sent back with at least 10 bar, so prepare the gas order in advance.

  arrow
2.Provide requested composition list For submitting the list of requested mole fractions, please use the following Excel template: Order form -reference gases.
  arrow
3.Bottles will be sent to you

Once the gases are prepared and calibrated the gas bottles will be sent to the address you specified in the ordering form. The paper work for transportation of dangerous goods will be prepared by the CAL lab.

Infomation the shipper needs:
UN number: 1002
Label: 2.2
Name: air, compressed
transport category: 3
Tunnel code: (E)

3 bottles are packed on a palette: 120 x 80 x 35 cm, weight ca. 150 kg.

bottles on palette

The shipping of the bottles is organized by the sender, which means CAL is taking care of getting the bollles to the stations, But the stations need to take care of sending them back.

  arrow
4.Send empty bottles back

Once the bottles are exchanged, please send the bottles back. Make sure the bottles have at least 10 bar.

The shipping of the bottles is organized by the sender, which means CAL is taking care of getting the bollles to the stations, But the stations need to take care of sending them back.

  The calibrated values will be sent to you and posted below.

 

 

Calibration results

last update: 23. January 2024

Bottle IDcalibration results
D481453data
D482764data
D879578data
D895456data
D895457data
D895458data
D895459data
D904292data
D904293data
D904294data
D904295data
D928411data
D928412data
D928413data
D928414data
D928415data
D928416data
D928417data
D928418data
D928419data
D928420data
D928421data
D928422data
D928423data
D928424data
D928425data
D928426data
D928427data
D928428data
D928429data
D928430data
D928431data
D928432data
D928433data
D928434data
D928438data
D928439data
D928440data
D928584data
D928585data
D928586data
D928587data
D928588data
D928589data
D928590data
D928591data
D928592data
D928593data
D928594data
D928595data
D928596data
D928597data
D928598data
D928599data
D928600data
D928601data
D928602data
D928603data
D928604data